NEW!!! Lower detection limit 0.01 ppmV | 10 ppbV
The wall mounted device AQUATRACE® - IV Typ W belongs to the group of AQUATRACE® - IV devices that serve as instruments for determination of traces of moisture / humidity traces.
They operate on the basis of P2O5 sensors and can be used for determining the moisture in corrosive and all other gases (except NH3) in the ppm range. The use in chlorine gas has been proven worldwide best.
The wall mounted units with IP 65 degree of protection (standalone) can be integrated directly in industrial plants. It is as a 1 or 2-channel device available.
Special features of the moisture meters of type AQUATRACE® - IV
- The operation of the Moisture meters ensues via a touchscreen display
- in 7 languages to be select
- Menu-driven operation and for various operating levels protected by password
- Measured values and operator actions are logged internally and can be read out via the USB interface
- The event logs are in CSV format as a daily file available
- The devices for measurement of traces of moisture / humidity traces are executed according with the latest NAMUR recommendations
- Production is carried out in close exclusive cooperation with the MSC Ltd electronic components, Grossroehrsdorf according to the latest industry standards
Additionally there are the following versions for your needs
- The AQUATRACE 19" – version is available as a 1-, 2-, 3-, or 4-channel device
- Laboratory device (portable version) is also available as a two-channel device.
|
Technical specifications |
Product: |
AQUATRACE® IV - Typ W, wall mount device, 1-2 channels |
|
Performance specifications |
Measuring range: |
0-2000 Vppm, dew point –100 ° C - 20 ° C, ranges deviating from the standard on request |
Accuracy: |
+/- 5% of the displayed value, at least 0.4 ppmV | optional 0.04 ppmV |
Response time: |
dry to wet: T90 <5 sec; Wet to dry: T90 <15 min |
Repeatability |
+/- 0.1 ppmV | optional +/- 0.02 ppmV |
Calibration |
traceable calibration certificate, n-point calibration/adjustment (optional) |
Display |
Touchscreen 800x480 pixels, color |
|
Every measuring channel |
Lower detection limit |
0.1 ppmV | optional: 0.01 ppmV |
Measuring range |
0-2000 Vppm |
Displayed value(s) |
In ppmV or Tp ° C (adjustable) |
Transmission rate |
32 bit |
Data log rate |
min. 2 s max 10 min |
Sensor detection |
automatically |
Automatic sensor test |
Automatically (fuction test) |
Analog output |
4-20 mA (freely scalable) |
Alarm output |
limit value - programmable as floating changeover contact |
Channel relay |
4 channel relays according to NAMUR (F + S; C + M), per channel (max. 2) |
|
Measuring cell |
Material measuring cell |
PVDF or stainless steel |
sensor material |
Platinum on glass / ceramic or interdigital structure on ceramic substrate |
Leakage rate |
< 5x10 -7 mbar x l / s |
Sample Gas flow |
20 Nl/h or 100 Nl/h cell |
Sample gas temperature |
+5 … +90 °C |
Sample gas pressure |
approx. 200 mbar overpressure at the measuring cell inlet, pressureless flow out |
Gas connections |
¼“ NPT inside thread |
Cell connection (el.) |
5-pin Binder plug, angled |
Measuring cable |
Customized 2 m; Max. Cable length 100 m |