Trust is good, but measuring is even better!
Designation: electrochemical cell
Produktbild OX600

Oxygen deficiency warning device

Stand-alone oxygen monitor

  • Works with or without a controller
  • Range of 0-25.0% volume with 0.1% increments
  • Three-color visual alarm indicator
  • 2 preset alarms; Green=Normal, Yellow=Alarm 1, Red=Alarm 2
  • Large, easy-to-read digital display
  • Three power options: 115 VAC, 24 VDC, or 2 AA alkaline
  • Works up to 1 year with a set of AA alkaline batteries
  • Pressure compensation avoids false alarms caused by pressure changes
  • Sensor cable available for remote mounting

Description of the oxygen meter

The OX-600 is a stand-alone indoor oxygen monitor. It can detect oxygen (O2) in a range of 0-25.0% volume in 0.1% increments. The sleek, low-profile design is equipped with a unique three-color display that changes color when oxygen levels reach the respective alert level. It can be operated with three different energy options; 115 VAC, 24 VDC or alkaline batteries. When oxygen is present, the user is notified by an audible alarm sound and the multi-color LED digital display.

The OX-600 uses a fast-reacting, low-cost plug-in electrochemical cell (electrochemical cell) cell sensor. This durable sensor can be replaced in the field without the need for special tools. The sensor can also be mounted remotely with an optional remote sensor cable.

Extension cords are available up to 20m (gradation: 3, 5, 10 or 20m).

Laboratories

  • cryogenic environments
  • Clean rooms
  • industrial gas plants
  • gas storage rooms
  • indoor surveillance
  • Iron and steel industry
  • warehouses
  • Tunnels and garages
  • Automotive service areas

Technical data and service description

Detection principle Galvanic cell
Detected gas Oxygen (O2)
Coverage 0 ~ 25 Vol%
Measured value resolution 0.1 vol%
Sampling method Diffusion or remote sampling method with optional extension cord
Accuracy of indication* Within ±0.7% by volume
Response time* 90% response within 30 seconds
Alarm delay time* Within 5 seconds, after detecting 10~11% by volume of gas in the event of oxygen deficiency alarm (18% alarm).
Alarm accuracy* Within ±1% by volume of preset alarms
Alert Levels Two preset alarms (L-LL), alarm 1 = 19.0% vol, alarm 2 = 18.0% vol (other settings available), 85dB (30cm distance)
Indication of the alarm

1. Gas alarm: gas concentration indicator flashing, orange light, AL1 LED flashing or steady lights, buzzer 85dB (30cm)

2. Gas alarm: gas concentration indicator flashing, red light, AL2 LED flashing or steady lights, buzzer 85dB ́(30cm)

Alarm method To lock or not to lock
Alarm Contact Dry contact, Form A or Form B, Form A standard factory setting, NO (closed in ALARM)
Display Digital LCD (3 digits, 7 segments / green, orange, red) (In the version with alkaline battery, the backlight is turned off during normal operation)
Fault alarm / self-diagnosis System errors / problems with the sensor connection
Indication of the disturbance alarm Buzzer/content indicator (flashing red error message)
Trouble Alarm Method Non-locking or locking
Contact Capacity 125 VAC, 1 A or 30 VDC, 1 A (resistive load)
Output signal 4~20mA (non-isolated, resistive load below 300 Ω) or 0DC-1V (non-isolated)*only for 0DC-1V alkaline battery specification
Extension cord Extension cord with remote box (3 m, 5 m, 10 m or 20 m length available)
Sources 120 VAC±10%, 50/60 Hz, 24 VDC±10% or AA alkaline battery (2 each)
Power consumption AC Specification: MAX 3.5 VA, DC Specification: MAX 2 W
Continuous operation (for alkaline battery version) 1 year (no alarm, no display)
Initial release approx. 25 seconds
Operating temperature 0~104°F (no sudden change)
Humidity during operation Below 90% relative humidity (non-condensing)
Accessories Wall-mounted, sensor integration type, or remote type
Dimension Case: Approx. 3.15" (W) x 4.72" (H) x 1.2" (D) (80 (W) x 120 (H) x 35.5 (D) mm) Remote Sensor: Approx. 1.57" (W) x 3.78" (H) x 1.2" (D) 40 (W) x 96 (H) x 35.5 (D) mm (without protrusion)
Weight AC specification: approx. 7.05 oz (200 g), DC specification: approx. 6.34 oz (180 g), alkaline battery specification: approx. 8.11 oz (230 g) Remote sensor: approx. 1.94 oz (55 g) (without cable)
Warranty One year of material and workmanship

*Under normal conditions

O2 Symptoms of oxygen starvation
23.5% OSHA Limit for Elevated Oxygen
20.9% Oxygen content in normal air
19.5% – 12% Increased pulse and increased breathing
12% – 10% Impaired breathing, fatigue, misjudgement
10% – 6% Nausea, vomiting, inability to move, loss of consciousness and death
6% – 0% Convulsions, cardiac arrest and death
« Back to overview