Designed for gas or general compressed air removal
Shaw Moisture Meters designed the SU4 to reduce the pressure of the gas pipeline. A pressure and flow rate is produced, which is suitable for measuring trace moisture in process gases and dry compressed air.
The SU4 probe system allows the sensor to work in normal conditions. Suitable for wall mounting.
The SU4 sample system conditions the flow of sample gas to the required 2-10 litres per minute at almost atmospheric pressure for accurate and consistent sampling. Pneumatic connections are available for enclosures and omissions if required. Choose from our selection of 1⁄4, 1⁄8" or 6 mm compression fittings.
Main features of the SU4-Sample Conditioning Unit
- Designed for gases or general compressed air removal
- Reduced inlet pressure of up to 210 bar (3045 psi)
- Adjustable sample flow of up to 10 litres per minute
- All stainless steel fittings and pipes
- Single and outlet fittings with a choice of 1⁄4, 1⁄8" or 6 mm compression fittings
- Dimensions: 260 mm (h) x 160 mm (w) x 135 mm (d)
- Approximate weight: 1.6 – 1.8 kg
- Sampling options: Input pressure (pr): Up to 200 bar (MED), 400 bar (HI)
- Wall mounted with 4 x 5 mm mounting holes at 240 mm (h) x 140 mm (w)
- Optional filter unit (only for 200 bar variants)
- Optional Firtree fittings for 6 mm id hose (low pressure only usually 8 bar)