Trust is good, but measuring is even better!
Designation: ATEX, IECEx, NEMA4X, IP66
Modell SDT-Ex

Dew point transmitters for compressed air and process gases

The SDT-Ex is an intrinsically safe dew point transmitter, developed for the continuous measurement of trace moisture in dry compressed air and process gases. It is particularly suitable for applications in the petrochemical and hydrogen industries. The transmitter works with 4-20 mA grinding operations and is certified according to ATEX and IECEx standards. It offers various output options, including °C dew point, °F dew point and ppm. The device is robust, weatherproof (IP66 NEMA 4X) and comes with a calibration certificate.

The SDT-Ex has advanced electronics and draws its current from a non-insulated 7-28 V DC power source. Configurable for output a linear, isolated 4-20 mA signal. This intrinsically safe dew point transmitter does not suffer signal loss if it is set up to 1,000 metres away from the display.

Using the SHAW moisture sensor technology with extremely high capacity, various dew point ranges are available, covering a total dew point range from -100 °C to +20 °C (-148 °F to +68 °F). The 4-20mA output can be configured for display in °C dew point, °F dew point, ppm(V), g/m3 and lb/MMSCF.

Fully housed in a robust housing to provide weatherproof protection according to IP66 NEMA 4X. The intrinsically safe dew point transmitter SDT-Ex is supplied ready for use with a calibration certificate traceable to national and international humidity standards, a user manual and a two-metre-long cable.

Key features of the SDT-Ex dew point transmitter:

  • intrinsically safe for explosive environments (ATEX & IECEx certified)
  • Auto calibration function
  • 4-20 mA loop performance
  • Measuring range: -100 °C to +20 °C dew point (optional -120°C dp)
  • traceable to national standard multipoint calibration certificate
  • Various output formats: °C/°F dew point, ppm
  • Weatherproof Housing (IP66 NEMA 4X)
  • Suitable for the petrochemical and hydrogen industries and more
  • Intrins & safely certified according to ATEX: Ex II 1 GD Ex ia IIC T4 Ga (-20 °C - Ta - +60 °C)
  • Certified according to IECEx: Ex ia IIIC T200135 °C Da (-20 °C - Ta - +60 °C)
  • For use in potentially explosive atmospheres when a signal insulator is used
  • 3-wire swax transmitter, 24 V, 4-20 mA
  • Detection of interruptions/shorteners
  • Linear 4-20 mA output signal

SDT-EX - (Measuring range R)

R - Select the desired measuring range:

ZD: -100 °C to +20 °C (-148 °F to +68 °F)
HD: -65 °C to +20 °C (-85 °F to +68 °F)
Go (Gold) -120 to -20 °C (-184 to -4 °F) Dew point 0.1 ppb – 1,000 ppm(V)
P (purple) -100 to 0 °C (-148 to +32 °F) Dew point 0 - 6,000 ppm(V)
S (silver) -100 to -20 °C (-148 to -4 °F) Dew point 0 - 1,000 ppm(V)
G (Grau)G (grey) -80 to 0 °C (-112 to +32 °F) Dew point 0 - 6.000 ppm(V)
R (Red) -80 to -20 °C (-112 to -4 °F) Dew point 0 - 1,000 ppm(V)
B (Blue) -80 to +20 °C (-112 to +68 °F) Dew point 0 - 23,000 ppm(V)
MP: 0.1 to 100.0 ppm(V)
LP: 0.01 to 10,00 ppm(V)
GH: 0.01 to 10.00 g/m3
LB: 0.1 to 100.0 lb/MMSCF

Example:
Order an AcuDew with a measuring range of -80 °C to 0 °C
(-112 °F to +32 °F) Dew point (grey sensor), please order as
SDT-EX-R

To order a sensor holder for use with SDT-ExF - Suitable size for sensor holders choose:
4: 1/4"| 8: 1/8" | 6: 6 mm
To order a sensor holder with a 6mm connection, please order as SDT-SEH-6

 

 