SONNTAG/HARDY · 1 INPUT VALUE → 11 PARAMETERS Input 45 %RH at 20 °C, 1 bar(a) Dew point t_d 7.7 °Ctd Absolute humidity A 7.78 g/m³ Volume ppm 10,527 ppmV Enthalpy h 36.9 kJ/kg Wet-bulb t_wb 13.1 °C Mixing ratio r 6.62 g/kg + Process A→B + Uncertainty + Purge and more
Calculation tool

Humidity Calculator

Converts between eleven gas humidity quantities — including relative humidity, dew point, frost point, ppm, enthalpy, wet-bulb temperature and mixing ratio. One input value is enough; all other quantities are calculated instantly using the Sonntag/Hardy equation.

New additions: process calculator A→B, uncertainty propagation and a purge/drying calculator.

Go to calculator →
SONNTAG/HARDY · ppmV ⇄ rH ⇄ dew/frost point Gas temperature relative to the frost point -80°C -40°C 0°C 40°C 80°C -59.0 °C Gas 20 °C 12.3 ppmV H₂O in process gas Volume ppm 12.30 ppmV Frost point t_f -59.0 °Ctf Relative humidity U 0.0526 %RH Saturation at 20°C 23,392 ppmV Recommendation: ppmV — well resolved here, RH collapses toward 0%
Interactive introduction

How humid is my gas?

Shows vividly how ppmV, relative humidity and dew/frost point describe the same quantity from three angles, and recommends at every slider setting which one is currently most meaningful. Sliders for water content, temperature and pressure let you see live why the same trace moisture means something completely different at −40 °C than at 20 °C.

Go to the introduction →